West Caldwell Water Department (NJ0721001) reported PFOA up to 8.3 ppt at Beverly Pit – Representative Intertie in UCMR5 sampling, 2023-07-18 to 2024-04-12 (EPA MCL 4 ppt); 1 of 1 filter we track is certified to reduce PFOA under NSF/ANSI 53 (PFOA/PFOS combined pass level 70 ppt).
PFAS results for West Caldwell Water Department (NJ0721001)
In plain words
This water system's highest reported PFOA result was 8.3 ppt (parts per trillion), at Beverly Pit – Representative Intertie in UCMR5 sampling, 2023-07-18 to 2024-04-12. The federal legal limit (EPA MCL) for PFOA is 4 ppt. Compliance is judged on a running yearly average at each sampling point, not on any single result.
Check the filter you ownWe track 1 filter so far. It is certified to reduce PFOA and PFOS under NSF/ANSI 53. That standard's pass level is 70 ppt for the two combined, set by the standard, not by the legal limit. No certified claim exists for PFBA, PFHxA or PFPeA under NSF/ANSI 53 or 58 (2022 editions).
Check the filter you own
Certified claims for the filter we track come from its manufacturer's performance data sheet. If your filter is not listed, we do not have its certification data, and we do not guess.
- Aquasana AQ-5300+ (replacement cartridge AQ-5300+R)Certified to reduce, of the compounds reported here: PFOA and PFOS.This filter's certification status for each of the seven PFAS with reduction requirements in the 2022 editions of NSF/ANSI 53 and 58, not only the compounds reported here: Aquasana AQ-5300+ (replacement cartridge AQ-5300+R): PFAS certification
PFAS compounds reported, and which filters we track are certified to reduce them
How to read this table: 'Highest level reported' is the single highest result in the dataset for that sampling point, not a yearly average. The legal limit is judged on a running yearly average at each sampling point. The certification pass level is the most a filter may leave in its treated water during the lab test; for PFOA and PFOS it applies to the two combined. The standard sets it, not the legal limit. These numbers come from different tests, so we do not subtract one from another or estimate what a filter would leave in your water.
Scroll sideways to see every column.
Many terms in this table are explained in Words on this page.
| Compound | Certification status | Highest level reported | Sampling point | Sample dates | Dataset | Legal limit and certification pass level |
|---|---|---|---|---|---|---|
| PFOA | Certified to reduce: 1 of 1 filter we track | 8.3 ppt | Beverly Pit – Representative Intertie | 2023-07-18 to 2024-04-12 | EPA Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) |
|
| PFOS | Certified to reduce: 1 of 1 filter we track | 5.5 ppt | Beverly Pit – Representative Intertie | 2023-07-18 to 2024-04-12 | EPA Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) |
|
| PFBA | Not scored: no certified claim exists under NSF/ANSI 53 or 58 (2022 editions) | 5.1 ppt | Beverly Pit – Representative Intertie | 2023-07-18 to 2024-04-12 | EPA Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) |
|
| PFHxA | Not scored: no certified claim exists under NSF/ANSI 53 or 58 (2022 editions) | 6.2 ppt | Beverly Pit – Representative Intertie | 2023-07-18 to 2024-04-12 | EPA Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) |
|
| PFPeA | Not scored: no certified claim exists under NSF/ANSI 53 or 58 (2022 editions) | 6.7 ppt | Beverly Pit – Representative Intertie | 2023-07-18 to 2024-04-12 | EPA Fifth Unregulated Contaminant Monitoring Rule (UCMR 5) |
|
Tested, not detected at or above the reporting level
These compounds were tested and not detected at or above the reporting level at any sampling point, so they have no row in the table above.
- PFBS: not detected at or above the 3 ppt reporting level in 4 samples at 1 sampling point, UCMR5 sampling, 2023-07-18 to 2024-04-12.
- PFDA: not detected at or above the 3 ppt reporting level in 4 samples at 1 sampling point, UCMR5 sampling, 2023-07-18 to 2024-04-12.
- PFHpA: not detected at or above the 3 ppt reporting level in 4 samples at 1 sampling point, UCMR5 sampling, 2023-07-18 to 2024-04-12.
- PFHxS: not detected at or above the 3 ppt reporting level in 4 samples at 1 sampling point, UCMR5 sampling, 2023-07-18 to 2024-04-12.
- PFNA: not detected at or above the 4 ppt reporting level in 4 samples at 1 sampling point, UCMR5 sampling, 2023-07-18 to 2024-04-12.
Certified claims, with their sources
PFOA: certified to reduce
Aquasana AQ-5300+ (replacement cartridge AQ-5300+R)
Certified to NSF/ANSI 53 for PFOA/PFOS by WQA under Aquasana, Inc., AQ-5300+.
Legal limit: EPA MCL (2024): 4 ppt. NSF/ANSI 53 combined PFOA + PFOS pass level: 70 ppt.
Rated life: 800 gallons (data sheet).
Manufacturer performance data sheet (PDF) Version date not printed on the data sheet; retrieved 2026-10-20.
PFOS: certified to reduce
Aquasana AQ-5300+ (replacement cartridge AQ-5300+R)
Certified to NSF/ANSI 53 for PFOA/PFOS by WQA under Aquasana, Inc., AQ-5300+.
Legal limit: EPA MCL (2024): 4 ppt. NSF/ANSI 53 combined PFOA + PFOS pass level: 70 ppt.
Rated life: 800 gallons (data sheet).
Manufacturer performance data sheet (PDF) Version date not printed on the data sheet; retrieved 2026-10-20.
PFAS compounds we do not score, and why
To 'score' a compound means to say which filters we track are certified to reduce it. When no certification claim exists, there is nothing to score, so we say so instead of guessing.
- PFBA, PFHxA and PFPeA, for each compound: NSF/ANSI 53 and 58, the standards EPA points to for PFAS reduction, set reduction requirements for seven PFAS in their 2022 editions: PFOA, PFOS, PFHxS, PFNA, PFHpA, PFBS and PFDA. This compound is not one of them, and no filter we track is certified for it, so we do not score it.
Read before acting on these numbers
- Levels are utility-reported results; your tap may differ.
- A certification pass level is the maximum concentration allowed in the test's treated water. It is set by the standard, not by the legal limit, and may be above the limit.
- Results are shown with the dates they were sampled. Utilities add treatment over time; check the date before acting on a number.
- Aquasana AQ-5300+ (replacement cartridge AQ-5300+R): Certified performance applies within the filter's rated capacity: 800 gallons.
Words on this page
- PFAS
- per- and polyfluoroalkyl substances, a large group of manufactured chemicals.
- Compound names
- short names of individual PFAS chemicals, such as PFOA (perfluorooctanoic acid) and PFOS (perfluorooctane sulfonic acid).
- ppt
- parts per trillion, the unit used here for PFAS results and limits. 1,000 ppt equals 1 part per billion (ppb).
- Reporting level
- the lowest amount EPA set for labs to report as a number in UCMR 5 testing (EPA calls it the minimum reporting level). A result below it is listed as not detected at or above the reporting level, which does not mean zero.
- PWSID
- Public Water System ID: the number EPA and the state use to identify a public water system.
- UCMR 5
- UCMR 5 (also written UCMR5): EPA's fifth Unregulated Contaminant Monitoring Rule, under which public water systems tested for PFAS and lithium starting in 2023. Each result on this page shows its sample dates.
- EPA MCL
- Maximum Contaminant Level: the federal legal limit for a public water system, judged on a running yearly average at each sampling point. "(2024)" is the year EPA issued the PFAS rule.
- NSF/ANSI 53
- NSF/ANSI 53 (Drinking Water Treatment Units – Health Effects): a standard for home drinking water filters. Its 2022 edition sets PFAS reduction requirements for seven compounds: PFOA, PFOS, PFHxS, PFNA, PFHpA, PFBS and PFDA.
- NSF/ANSI 58
- NSF/ANSI 58 (Reverse Osmosis Drinking Water Treatment Systems): a standard for home reverse osmosis systems. Its 2022 edition sets PFAS reduction requirements for the same seven compounds.
- Pass level
- the most of a compound the standard allows in the filter's treated water during the lab test (for PFOA and PFOS, the two combined). The standard sets it, not the legal limit.
- Certified
- a certifier lists this model as meeting a standard's requirements for that compound. It describes a lab test, not a measurement of your water.
- Certification claim
- a reduction claim a standard offers, with its own lab test and pass level. Most are for one compound; for PFOA and PFOS, the claim is for the two combined. A filter model is certified only for the claims its certifier lists it for.
- WQA
- the Water Quality Association, a trade association that also runs an accredited program certifying water treatment products.
- Sampling point / entry point
- the place a sample was taken. An entry point is where treated water enters the distribution pipes, usually at a treatment plant. Neither is your tap.
- Federal Register (FR)
- the U.S. government's official daily publication of federal rules, proposed rules and notices. "89 FR 32532" means volume 89, starting at page 32532.
- Dataset
- the published set of results a number comes from, named in the Dataset column.
- Filters we track
- the filters whose manufacturer performance data sheets we have entered. A filter not on our list may still be certified; we do not have its data.
- Score
- to say which filters we track are certified to reduce a compound.
- Performance data sheet
- the manufacturer's document listing a filter's certified claims, pass levels and rated life; it is our source for every certified claim.
- Rated life
- how much water a cartridge is certified to treat, from its data sheet; certified performance applies only within it.
Sources
Detection data: EPA Fifth Unregulated Contaminant Monitoring Rule (UCMR 5).
EPA's public water system database (SDWIS) lists this system as WEST CALDWELL WATER DEPARTMENT, serving a population of 10,759 (retrieved 2026-10-23).
EPA's UCMR5 data lists this system as WEST CALDWELL WATER DEPARTMENT.
Each level is the highest result the dataset reports for that sampling point, shown as published with its sampling point and sample date range.