Aquasana AQ-5300+ (replacement cartridge AQ-5300+R) is certified to reduce PFOA under NSF/ANSI 53 (NSF/ANSI 53 pass level: 70 ppt for PFOA and PFOS combined; EPA MCL for PFOA: 4 ppt), which Totowa W Dept (NJ1612001) reported in UCMR5 sampling, 2024-09-30 to 2025-07-02.

Aquasana AQ-5300+ (replacement cartridge AQ-5300+R) and the PFAS results reported by Totowa W Dept (NJ1612001)

Own a different filter? All PFAS results for Totowa W Dept (NJ1612001), and every filter we track

PFAS compounds Totowa W Dept reported, and this filter's certification status for each

How to read this table: 'Highest level reported' is the single highest result in the dataset for that sampling point, not a yearly average. The legal limit is judged on a running yearly average at each sampling point. The certification pass level is the most a filter may leave in its treated water during the lab test; for PFOA and PFOS it applies to the two combined. The standard sets it, not the legal limit. These numbers come from different tests, so we do not subtract one from another or estimate what a filter would leave in your water.

Scroll sideways to see every column.

Many terms in this table are explained in Words on this page.

CompoundCertification statusHighest level reportedSampling pointSample datesDatasetLegal limit and certification pass level
PFOACertified to reduce7.2 pptPVWC Consecutive Connection – Representative Intertie2024-09-30 to 2025-07-02EPA Fifth Unregulated Contaminant Monitoring Rule (UCMR 5)
  • EPA MCL 4 ppt (2024 rule, 89 FR 32532)
  • NSF/ANSI 53 combined PFOA + PFOS pass level: 70 ppt
PFHxANot scored: no certified claim exists under NSF/ANSI 53 or 58 (2022 editions)3.7 pptPVWC Consecutive Connection – Representative Intertie2024-09-30 to 2025-07-02EPA Fifth Unregulated Contaminant Monitoring Rule (UCMR 5)
  • No federal legal limit
PFPeANot scored: no certified claim exists under NSF/ANSI 53 or 58 (2022 editions)3.8 pptPVWC Consecutive Connection – Representative Intertie2024-09-30 to 2025-07-02EPA Fifth Unregulated Contaminant Monitoring Rule (UCMR 5)
  • No federal legal limit

Tested, not detected at or above the reporting level

These compounds were tested and not detected at or above the reporting level at any sampling point, so they have no row in the table above.

Certified claims, with their sources

PFOA: certified to reduce

Certified to NSF/ANSI 53 for PFOA/PFOS by WQA under Aquasana, Inc., AQ-5300+.

Legal limit: EPA MCL (2024 rule, 89 FR 32532): 4 ppt for PFOA. NSF/ANSI 53 combined PFOA + PFOS pass level: 70 ppt.

Rated life: 800 gallons (data sheet).

Manufacturer performance data sheet (PDF) Version date not printed on the data sheet; retrieved 2026-10-20.

PFAS compounds we do not score, and why

The filter this page is about

Brand and model: Aquasana AQ-5300+.

Replacement cartridge: AQ-5300+R.

Listed by WQA under Aquasana, Inc. as AQ-5300+.

Rated life: 800 gallons (data sheet).

Manufacturer performance data sheet (PDF) Version date not printed on the data sheet; retrieved 2026-10-20.

Aquasana AQ-5300+ (replacement cartridge AQ-5300+R): PFAS certification

Read before acting on these numbers

Words on this page

PFAS
per- and polyfluoroalkyl substances, a large group of manufactured chemicals.
Compound names
short names of individual PFAS chemicals, such as PFOA (perfluorooctanoic acid) and PFOS (perfluorooctane sulfonic acid).
ppt
parts per trillion, the unit used here for PFAS results and limits. 1,000 ppt equals 1 part per billion (ppb).
Reporting level
the lowest amount EPA set for labs to report as a number in UCMR 5 testing (EPA calls it the minimum reporting level). A result below it is listed as not detected at or above the reporting level, which does not mean zero.
PWSID
Public Water System ID: the number EPA and the state use to identify a public water system.
UCMR 5
UCMR 5 (also written UCMR5): EPA's fifth Unregulated Contaminant Monitoring Rule, under which public water systems tested for PFAS and lithium starting in 2023. Each result on this page shows its sample dates.
EPA MCL
Maximum Contaminant Level: the federal legal limit for a public water system, judged on a running yearly average at each sampling point. "(2024)" is the year EPA issued the PFAS rule.
NSF/ANSI 53
NSF/ANSI 53 (Drinking Water Treatment Units – Health Effects): a standard for home drinking water filters. Its 2022 edition sets PFAS reduction requirements for seven compounds: PFOA, PFOS, PFHxS, PFNA, PFHpA, PFBS and PFDA.
NSF/ANSI 58
NSF/ANSI 58 (Reverse Osmosis Drinking Water Treatment Systems): a standard for home reverse osmosis systems. Its 2022 edition sets PFAS reduction requirements for the same seven compounds.
Pass level
the most of a compound the standard allows in the filter's treated water during the lab test (for PFOA and PFOS, the two combined). The standard sets it, not the legal limit.
Certified
a certifier lists this model as meeting a standard's requirements for that compound. It describes a lab test, not a measurement of your water.
WQA
the Water Quality Association, a trade association that also runs an accredited program certifying water treatment products.
Sampling point / entry point
the place a sample was taken. An entry point is where treated water enters the distribution pipes, usually at a treatment plant. Neither is your tap.
Federal Register (FR)
the U.S. government's official daily publication of federal rules, proposed rules and notices. "89 FR 32532" means volume 89, starting at page 32532.
Dataset
the published set of results a number comes from, named in the Dataset column.
Filters we track
the filters whose manufacturer performance data sheets we have entered. A filter not on our list may still be certified; we do not have its data.
Score
to say which filters we track are certified to reduce a compound.
Performance data sheet
the manufacturer's document listing a filter's certified claims, pass levels and rated life; it is our source for every certified claim.
Rated life
how much water a cartridge is certified to treat, from its data sheet; certified performance applies only within it.
Twp, Boro, W Dept, Div
abbreviations in water system names: Twp is township, Boro is borough, W Dept is water department, and Div is division.

Sources

Detection data: EPA Fifth Unregulated Contaminant Monitoring Rule (UCMR 5).

EPA's UCMR5 data lists this system as TOTOWA W DEPT.

Each level is the highest result the dataset reports for that sampling point, shown as published with its sampling point and sample date range.

All PFAS results for Totowa W Dept (NJ1612001), and every filter we track

This page's data as JSON